Constant Pressure Precision: How DR Control Works on the A10VO28 Hydraulic Pump
Constant Pressure Precision: How DR Control Works on the A10VO28 Hydraulic Pump
The Industrial Challenge of Sustained Pressure
In industrial hydraulic power units (HPUs), plastic injection molding clamps, machine tool clamping jigs, and hydraulic presses, system efficiency depends on managing standby power. Traditional fixed-displacement pumps continuously force full fluid volume through relief valves during pressure-holding phases. This constant dumping of high-pressure fluid converts mechanical energy into heat, raising oil temperatures, degrading seals, and wasting electric power.

The A10VO28 Axial Piston Variable Pump equipped with a DR (Pressure Control) valve solves this thermal and energetic inefficiency. By combining a compact 28 cm³/rev displacement with a responsive hydromechanical pressure limiter, the pump dynamically balances maximum system pressure with near-zero flow output during holding cycles.
How the DR Pressure Cut-Off Mechanism Operates
The DR valve functions as an automatic displacement limiter. Unlike load-sensing (DFR) controls that track load differential pressure, the DR controller monitors absolute system pressure against an adjustable internal spring setting.
-
Flow Phase (Pressure Below Setting): When working pressure is below the set point, an internal bias spring pushes the pump's swashplate to its maximum swivel angle. The pump delivers maximum flow ($28 \text{ cm}^3\text{/rev}$) to actuate hydraulic cylinders or motors rapidly.
-
Destroking Phase (Pressure Reaches Setting): As the hydraulic actuator meets resistance and system pressure reaches the preset limit (e.g., 210 bar), high-pressure fluid overcomes the DR valve spring force.
-
Standby / Zero-Stroke Phase: The DR spool shifts, directing pilot fluid to the positioning chamber. This overcomes the bias spring and destrokes the swashplate toward a minimum angle, supplying only enough oil flow to compensate for internal component leakage.
The theoretical hydraulic power consumed during zero-stroke holding drops significantly:
Where:
-
$P_{standby}$ is the standby power draw in kilowatts (kW).
-
$p_{set}$ is the target cut-off pressure in bar.
-
$Q_{leak}$ is the minimal internal leakage flow in L/min required to maintain pressure and lubrication.
-
$\eta_t$ is the overall efficiency.

Core Engineering Benefits for Industrial HPUs
-
Drastic Energy Savings: Power consumption drops by up to 80% during long pressure-holding phases compared to fixed-displacement pump circuits.
-
Reduced Thermal Load: Eliminating high-pressure relief valve dumping prevents oil overheating, eliminating the need for oversized water or air oil coolers.
-
High Power Density in a 28cc Frame: The compact Series 31 housing fits tightly into small machine frames while providing up to 280 bar continuous pressure capability.
-
Clockwise (R) Rotational Precision: The 31R configuration ensures balanced valve plate mechanics optimized for standard clockwise electric motor drives.
A10VO28DR31R Technical Specifications
| Technical Metric | Specification Value |
| Model Code | A10VO28DR/31R-VSC12N00 |
| Nominal Displacement ($V_g$) | $28 \text{ cm}^3\text{/rev}$ |
| Nominal Operating Pressure ($p_{nom}$) | 280 bar (4060 psi) |
| Maximum Peak Pressure ($p_{max}$) | 350 bar (5075 psi) |
| Control Type | DR (Pressure Control / Pressure Limiter) |
| Rotation Direction | Clockwise (R) |
| Series Generation | Series 31 |
| Maximum Rated Speed | 3000 rpm |
| Output Flow (at 1500 rpm) | $\approx 42 \text{ L/min}$ |

Q1: What is the main operational difference between DR control and DFR control on an A10VO28 pump?
Answer: A DR control is a pure pressure limiter (constant pressure control). It maintains the pump at maximum displacement until the system pressure reaches the preset limit, at which point it destrokes the swashplate to zero flow while holding that pressure. A DFR control (Load Sensing) is a dual-parameter valve that adjusts flow based on both working pressure and a differential pressure signal ($\Delta p$) from a proportional directional valve. Choose DR for simple pressure-clamping or pressure-holding hydraulic power units; choose DFR for multi-actuator machinery requiring variable speed and proportional flow control.
Q2: How do I adjust the cut-off pressure on the A10VO28DR31R pump?
Answer: The pressure cut-off setting is adjusted via the set screw located on the DR valve body integrated into the pump housing. Loosen the locknut and turn the adjustment screw clockwise to increase the pressure cut-off point, or counter-clockwise to lower it. Always perform this adjustment while monitoring a calibrated high-pressure gauge attached to the pump's gauge port, and ensure you do not exceed the pump's 280 bar continuous or 350 bar peak operating rating.
Q3: Why is my A10VO28DR31R pump overheating even though it is fitted with a DR valve?
Answer: Overheating in a DR-controlled pump typically stems from three causes: an improperly adjusted DR valve that never allows the pump to destroke fully; excessive internal wear (worn valve plate or piston slippers) causing high internal bypass leakage back to the case drain under pressure; or an improperly set system main relief valve. Ensure the main system relief valve is set at least 20 to 30 bar higher than the DR pump cut-off setting. If the system relief valve is set lower than the DR valve, oil will dump over the relief valve indefinitely before the pump can ever destroke itself.